Purpose, Scope and General Statements
1.1 The
Standards of Practice (Standards) provide the
minimum standards of performance for a written
report on a residential home inspection performed
by a member of the National Association of Home
Inspectors, Inc. (NAHI).
1.2 The
Standards define and clarify the purpose,
conditions, limitations, exclusions, and certain
terms relating to an inspection.
1.3 The
Standards identify those items, components, and
systems included in the scope of an inspection.
1.4 The
Standards apply only to the inspection of
buildings with one (1) to four (4) dwelling
units.
1.5 The
Standards apply to a visual inspection of the
readily accessible areas of the included items,
components, and systems to determine if, at the
time of the inspection, they are performing their
intended function without regard to life
expectancy.
1.6 The
purpose of the inspection is to identify visible
defects and/or conditions that, in the judgement
of the Inspector, adversely affect the function
and/or integrity of the items, components, and
systems inspected with the health and safety of
the dwelling occupant(s) in mind.
1.7
Inspections performed under the Standards are
basically visual and rely upon the opinion,
judgement, and experience of the Inspector, and
are not intended to be technically exhaustive.
1.8
Inspections shall be performed in a time period
sufficient to allow compliance with the
provisions of the Standards.
1.9
Inspections performed under the Standards shall
not be construed as a compliance inspection of
any code or governmental regulation. In the event
a law, statute, or ordinance prohibits a
procedure recommended in the Standards, the
Inspector is relieved of the obligation to adhere
to the prohibited part of the Standards.
1.10
Inspections performed under the Standards are not
an expressed or implied warranty or a guarantee
of the adequacy, performance, or useful life of
any item, component, or system in, on, or about
the inspected property.
1.11
Detached building(s) and detached garage(s)
located on the property will be inspected under
these Standards only if specifically listed in
the inspection report.
1.12 The
National Association of Home Inspectors
recommends that its members perform inspections
in accordance with these Standards, the Code of
Ethics, and applicable law(s). The Standards are
not intended to limit members from performing "additional
inspection services."
2.
General Limitations and Exclusions
2.1
Inspections performed under the Standards exclude
any item(s) concealed or not readily accessible
to the Inspector. The Inspector is not required
to move furniture, personal, or stored items;
lift floor coverings; move attached wall, ceiling
coverings, or panels; or perform any test(s) or
procedures(s) which could damage or destroy the
item(s) being evaluated.
2.2 The
following are excluded and not limited to:
appliances, recreational facilities, alarms,
intercoms, speaker systems, radio controlled
devices, security devices and lawn irrigation
systems.
2.3 The
determination of the presence of or damage caused
by termites or any other wood-damaging insects or
organism is excluded.
2.4 The
Inspector is not responsible for the
determination of air quality, presence of
airborne substances and conditions, or odors that
may be harmful or unpleasant to certain
individuals or animals.
2.5 Use of
special instruments or testing devices, such as
amp meters, pressure gauges, moisture meters, gas
detectors and similar equipment is not required.
2.6 The
inspection is not required to include information
from any source concerning previous property,
geological, environmental or hazardous waste
conditions, or manufacturer recalls or
information contained in Consumer Protection
Bulletin. The inspection is not required to
include information from any source concerning
past or present violations of codes, ordinances,
or regulations.
2.7 The
inspection and report are opinions only, based
upon visual observation of existing conditions of
the inspected property at the time of the
inspection. THE REPORT IS NOT INTENDED TO BE,
OR TO BE CONSTRUED AS, A GUARANTEE, WARRANTY, OR
ANY FORM OF INSURANCE. The Inspector will not
be responsible for any repairs or replacements
with regard to the property or the contents
thereof.
2.8 The
Inspector is not required to determine property
boundary lines or encroachments.
2.9 The
inspector is not required to provide an
inspection of any condominium common component,
system or evaluate condominium reserve accounts.
3. Site
3.1
Components for Inspection.
3.1.1
Building perimeter, land grade, and water
drainage directly adjacent to the foundation.
3.1.2 Trees
and vegetation that adversely affect the
structure.
3.1.3
Walks, grade steps, driveways, patios, and
retaining walls contiguous with the structure.
3.2
Procedures for Inspection.
The
Inspector will:
3.2.1
Describe material and inspect the condition of
the driveways, walkways, grade steps, patios, and
other items contiguous with the inspected
structure.
3.2.2
Observe the drainage, grading, and vegetation for
conditions that adversely affect the structure.
3.3
Limitations.
The
Inspector is not
required to:
3.3.1
Inspect fences or privacy walls.
3.3.2
Evaluate the condition of trees, shrubs, and or
other vegetation.
3.3.3
Evaluate or determine soil or geological
conditions, site engineering, or property
boundaries.
4.
Foundations
4.1
Components for Inspection.
4.1.1
Foundation walls, first-floor systems, other
support and sub-structure components, stairs.
4.1.2
Ventilation (when applicable).
4.1.3 Grade
slab and/or floor slab.
4.2
Procedures for Inspection.
The
Inspector will:
4.2.1
Identify the type of structure and material
comprising the structure and other items
inspected.
4.2.2
Observe the condition and serviceability of
visible, exposed areas of foundation walls, grade
slab, bearing walls, posts, piers, beams, joists,
trusses, subfloors, chimney foundations, stairs,
and other similar structural components.
4.2.3
Inspect foundations for indications of flooding,
moisture, or water penetration.
4.2.4
Observe subfloor crawl space ventilation and
vapor barriers.
4.2.5
Operate the sump pump when present.
4.2.6
Inspect the visible and accessible wooden
members.
4.2.7
Observe the visible condition of floor slab when
present.
4.3
Limitations.
The
Inspector is not
required to:
4.3.1 Enter
subfloor crawl spaces with headroom of less than
3 feet, obstructions, or other detrimental
conditions.
4.3.2 Move
stored items or debris or perform excavation to
gain access.
4.3.3 Enter
areas which may contain material hazardous to the
health and safety of the Inspector.
4.3.4
Operate sump pumps equipped with internal/water
dependent switches.
5.
Exterior
5.1
Components for Inspection.
5.1.1
Visible structural components.
5.1.2 Wall
covering, trim, and protective coating.
5.1.3
Windows and doors.
5.1.4
Attached porches, decks, steps, balconies,
handrails, guardrails, and carports.
5.1.5
Visible exterior portions of chimneys.
5.2
Procedures for Inspection.
The
Inspector will:
5.2.1
Identify the type and material comprising the
exterior components inspected.
5.2.2
Observe the condition of the components from the
ground level.
5.2.3
Observe the condition of a representative number
of visible windows and doors.
5.2.4
Inspect attached porches, decks, steps,
balconies, handrails, guardrails and carports.
5.3
Limitations.
The
Inspector is not
required to:
5.3.1
Inspect buildings, decks, patios, and other
structures detached from the house.
5.3.2
Evaluate function of shutters, awnings, storm
doors, storm windows and similar accessories.
5.3.3
Inspect or test the operation of security locks,
devices, or systems.
5.3.4
Evaluate the presence, extent, and type of
insulation and vapor barriers in the exterior
walls.
5.3.5
Examine the interior of the chimney flues or
determine the presence or absence of flu liners.
5.3.6
Inspect for safety type glass or the integrity of
thermal window seals or damaged glass.
6. Roof
Coverings, Flashings, Gutters, and Downspouts
6.1
Components for Inspection.
6.1.1 Roof
covering material.
6.1.2 Rain
gutter and downspout system.
6.1.3
Visible portions of roof flashings.
6.1.4 Roof
ventilation.
6.1.5 Roof
soffits and fascias.
6.1.6 Roof
skylights and other roof accessories.
6.2
Procedures for Inspection.
The
Inspector will:
6.2.1
Describe type of roofing and gutters.
6.2.2
Observe the condition of visible roof material,
rain gutter and downspout systems, visible
portions of roof flashings, roof soffits and
fascias, roof vents, skylights and other roof
accessories visible from the exterior.
6.2.3 If
possible, inspect the roof surface and components
from arms-length distance or with binoculars from
the ground.
6.2.4
Inspect flat roofs where internal accessibility
is readily and safely available.
6.3
Limitations.
The
Inspector is not
required to:
6.3.1 Walk
on or access a roof where it could damage the
roof or roofing material or be unsafe for the
Inspector.
6.3.2
Remove snow, ice, debris or other conditions that
prohibit the observation of the roof surfaces.
6.3.3
Inspect internal gutter and downspout systems and
related underground drainage piping.
6.3.4
Inspect antennas, lightning arresters, or similar
attachments.
7. Roof
Structure, Attic and Insulation
7.1
Components for Inspection.
7.1.1 Roof
framing, sheathing and decking.
7.1.2 Attic
insulation and ventilation.
7.2
Procedures for Inspection.
The
Inspector will:
7.2.1
Describe material comprising the roof structure
in the visible attic area.
7.2.2
Observe the condition of the visible roof
structure and attic components where readily and
safely accessible.
7.2.3
Investigate evidence of the presence of water
penetration.
7.2.4
Determine the presence of attic insulation and
its approximate thickness.
7.3
Limitations.
The
Inspector is not
required to:
7.3.1 Enter
attic spaces not readily accessible, if headroom
is less than 3 feet, or if inspection could
damage ceilings or insulation.
7.3.2 Break
or otherwise damage the surface finish or weather
seal on or around access panels and covers.
7.3.3
Operate powered roof ventilators.
8.
Attached Garage(s)/Carport(s)
8.1
Components for Inspection.
8.1.1
Exterior and interior walls and ceilings, floors,
windows, doors, roof, and foundation.
8.1.2
Electrical system and components.
8.1.3
Plumbing system and components.
8.1.4
Heating systems or units.
8.2
Procedures for Inspection.
The
Inspector will:
8.2.1
Identify type and material of door(s), exterior
walls, roof (if applicable), and other items to
be inspected.
8.2.2
Observe the condition and function of listed
components; electric, plumbing, heating and
similar systems.
8.2.3 Check
the condition and operation of accessible garage
door(s).
8.3
Limitations.
The
Inspector is not
required to:
8.3.1
Inspect or operate equipment housed in the garage
area except as otherwise addressed in the
Standards.
8.3.2
Operate the auto reverse function of a vehicle
door if the condition or type indicates possible
damage could occur from such operation.
9.
Electrical
9.1
Components for Inspection.
9.1.1
Entrance of the primary service from masthead to
main panel.
9.1.2 Main
and sub-panels including feeders.
9.1.3
Branch circuits, connected devices, and lighting
fixtures.
9.2
Procedures for Inspection.
The
Inspector will:
9.2.1
Identify type and location of primary service
(overhead or underground), voltage, amperage, and
over-current protection devices (fuses or
breakers).
9.2.2
Observe the existence of a connected grounding
conductor when readily accessible.
9.2.3
Inspect the main and branch circuit conductors
for proper over current protection and condition
by visual observation after removal of the
readily accessible main and sub electric panel
cover(s).
9.2.4
Determine presence of aluminum branch circuit
wiring at the main and sub-panels.
9.2.5 Test
and/or verify operation of a representative
number of accessible switches, receptacles and
light fixtures.
9.2.6 Test
and/or verify grounding and polarity of a
representative number of receptacles in proximity
to plumbing fixtures or on the exterior.
9.2.7
Verify operation of ground fault circuit
interrupters (GFCI), if present.
9.2.8
Observe the general condition of visible branch
circuit conductors that may constitute a hazard
to the occupant or the structure by reason of
improper use or installation of electrical
components.
9.3
Limitations.
The
Inspector is not
required to:
9.3.1
Insert any tool, probe or testing device into the
main or sub-panels.
9.3.2
Activate electrical systems or branch circuits
which are not energized.
9.3.3
Operate overload protection devices.
9.3.4
Inspect ancillary systems, including but not
limited to: burglar alarms, home protection
systems, low voltage relays, smoke/heat
detectors, antennas, electrical de-icing tapes,
sprinkler wiring, swimming pool wiring, or any
systems controlled by timers.
9.3.5 Move
any objects, furniture, or appliances to gain
access to any electrical component.
9.3.6 Test
every switch, receptacle, and fixture.
9.3.7
Remove switch and outlet cover plates.
9.3.8
Inspect electrical equipment not readily
accessible or dismantle any electrical device or
control.
9.3.9
Verify continuity of connected service ground(s).
10.
Plumbing
10.1
Components for Inspection.
10.1.1
Visible water supply lines.
10.1.2
Visible waste/soil and vent lines.
10.1.3
Fixtures and faucets.
10.1.4
Domestic hot water system and fuel source.
10.2
Procedures for Inspection.
The
Inspector will:
10.2.1
Identify material of the main line and water
supply lines.
10.2.2
Verify the presence of a main water supply valve.
10.2.3
Identify type of sanitary waste piping.
10.2.4
Identify type and capacity of domestic water
heating unit(s).
10.2.5
Inspect the condition of accessible and visible
water and waste lines.
10.2.6
Inspect and operate fixtures and faucets.
10.2.7
Inspect and operate the domestic hot water
system.
10.2.8
Inspect and operate drain pumps and waste ejector
pumps when possible.
10.2.9 Test
the water supply for functional flow.
10.2.10
Test waste lines from sinks, tubs and showers for
functional drainage.
10.3
Limitations.
The
Inspector is not
required to:
10.3.1
Operate any main, branch or fixture valve, except
faucets, or determine water temperature.
10.3.2
Inspect any system that is shut-down or secured.
10.3.3
Inspect any plumbing components not readily
accessible.
10.3.4
Inspect any exterior plumbing components or
interior or exterior drain systems.
10.3.5
Inspect interior fire sprinkler systems.
10.3.6
Evaluate the potability of any water supply.
10.3.7
Inspect water conditioning equipment, including
softener and filter systems.
10.3.8
Operate freestanding or built-in appliances.
10.3.9
Inspect private water supply systems.
10.3.10
Test shower pans, tub and shower surrounds, or
enclosures for leakage.
10.3.11
Inspect gas supply system for materials,
installation or leakage.
10.3.12
Evaluate the condition and operation of water
wells and related pressure tanks and pumps; the
quality or quantity of water from on-site water
supplies; or the condition and operation of
on-site sewage disposal systems such as
cesspools, septic tanks, drain fields, related
underground piping, conduit, cisterns, and
equipment.
10.3.13
Inspect and operate fixtures and faucets if the
flow end of the faucet is connected to an
appliance.
10.3.14
Record location of any on-site visible fuel tanks
within or directly adjacent to structure.
11.
Central Heating
11.1
Components for Inspection.
11.1.1 Fuel
source.
11.1.2
Heating equipment.
11.1.3
Heating distribution.
11.1.4
Operating controls.
11.1.5 Flue
pipes, chimneys and venting.
11.1.6
Auxiliary heating units.
11.2
Procedures for Inspection.
The
Inspector will:
11.2.1
Identify the type of fuel, heating equipment, and
heating distribution system.
11.2.2
Operate the system using normal control devices
to determine function.
11.2.3 Open
access panels or covers provided by the
manufacturer or installer, if readily detachable.
11.2.4
Observe the condition of normally operated
controls and components of the systems.
11.2.5
Observe visible flue pipes, dampers and related
components for safe operation.
11.2.6
Observe the condition of a representative number
of heat sources in each area of the house.
11.2.7
Inspect the installation and operation of fixed
supplementary heat units.
11.3
Limitations.
The
Inspector is not
required to:
11.3.1
Activate or operate heating or other systems that
have been shut-down.
11.3.2
Activate or operate heating systems that do not
respond to normal controls.
11.3.3
Inspect equipment or remove covers or panels that
are not readily accessible.
11.3.4
Dismantle any equipment, controls, or gauges.
11.3.5
Inspect the interior of chimney flues.
11.3.6
Inspect heating system accessories, such as
humidifiers, air purifiers, motorized dampers,
heat reclaimers, etc.
11.3.7
Inspect solar heating systems.
11.3.8
Activate heating, heat pump systems, or other
systems when ambient temperatures or other
circumstances are not conducive to safe operation
or may damage the equipment.
11.3.9
Evaluate the type of material contained in
insulation and/or wrapping of pipes, ducts,
jackets and boilers.
11.3.10
Operate digital-type thermostats or controls.
11.3.11
Evaluate the capacity, adequacy, or efficiency of
a heating or cooling system.
11.3.12
Test or operate fireplaces, gas logs, built-in
gas burning appliances, grills, stoves, space
heaters, or solar heating devices.
11.3.13
Determine clearance to combustibles.
12.
Central Air Conditioning
12.1
Components for Inspection.
12.1.1
Cooling equipment.
12.1.2
Cooling distribution.
12.1.3
Operating controls.
12.2
Procedures for Inspection.
The
Inspector will:
12.2.1
Identify the type of central air conditioning
system and energy sources.
12.2.2
Operate the system using normal control devices.
12.2.3 Open
access panels or covers provided by the
manufacturer or installer, if readily accessible.
12.2.4
Observe the condition of controls and operative
components of the complete system, conditions
permitting.
12.2.5
Observe the condition of a representative number
of the central air cooling outlets in each
habitable area of the house.
12.3
Limitations.
The
Inspector is not
required to:
12.3.1
Activate or operate cooling or other systems that
have been shut down.
12.3.2
Inspect gas-fired refrigeration systems,
evaporative coolers, or wall or window-mounted
air conditioning units.
12.3.3
Check the pressure of the system coolant or
determine the presence of leakage.
12.3.4
Evaluate the capacity, efficiency, or adequacy of
the system.
12.3.5
Operate equipment or systems if exterior
temperature is below 60° Fahrenheit or when other
circumstances are not conducive to safe operation
or may damage the equipment.
12.3.6
Remove covers or panels that are not readily
accessible.
12.3.7
Dismantle any equipment, controls, or gauges.
12.3.8
Check the electrical current drawn by the unit.
12.3.9
Operate digital-type thermostats or controls.
13.
Interior
13.1
Components for Inspection.
13.1.1
Walls, ceilings, floors, windows, and doors.
13.1.2
Steps, stairways, balconies, railings.
13.1.3
Fireplaces.
13.1.4
Electric outlets and fixtures.
13.1.5
Plumbing fixtures and components.
13.1.6
Heating and cooling distribution.
13.2
Procedures for Inspection.
The
Inspector will:
13.2.1
Observe the visible condition of the surfaces of
walls, ceilings, and floors relative to
structural integrity and evidence of water
penetration.
13.2.2
Verify the presence of steps, stairways,
balconies, handrails and guardrails and observe
their condition.
13.2.3
Describe type, material, condition and operation
of a representative number of windows, doors and
their hardware.
13.2.4
Inspect the exterior condition of the kitchen
cabinets and countertops.
13.2.5
Observe the condition of fireplaces, dampers,
fire boxes and hearths readily visible.
13.2.6
Locate and observe a representative number of
electrical outlets/fixtures and wiring in each
room as described in Section 9.
13.2.7
Comment on presence or absence of smoke
detectors.
13.2.8
Observe condition and operation of plumbing
fixtures and components in each room as described
in Section 10.
13.2.9
Observe a representative number of heat and/or
air conditioning sources and returns, if
applicable, in each room as described in Sections
11&12.
13.3
Limitations.
The
Inspector is not
required to:
13.3.1
Ignite fires in a fireplace or stove to determine
the adequacy of draft, perform a chimney smoke
test, or inspect any solid fuel device in use.
13.3.2
Evaluate the installation or adequacy of inserts,
wood burning stoves, or other modifications in a
fireplace, stove, or chimney.
13.3.3
Determine clearance to combustibles in concealed
areas.
13.3.4
Determine cosmetic condition of ceilings, walls,
floor coverings, and components.
GLOSSARY OF TERMS
Activate:
To turn on, supply power, or enable systems,
equipment, or devices to become active by normal
control means. Examples include turning on the
gas or water supply valves to the fixtures and
appliances and activating electrical breakers or
fuses.
Additional
Inspection Services: Those services offered
in addition to the home inspection as defined in
these standards, including but not limited to the
following examples; wood destroying
insect-organism and environmental testing.
Adversely
Affect: Constitute, or potentially
constitute, a negative or destructive impact.
Appliance:
A household device operated by use of electricity
or gas. Not included in this definition are
components cover under central heating, central
cooling, or plumbing.
Evaluate:
To ascertain, judge, or form an opinion about an
item or condition.
Foundation:
The base upon which the structure or a wall
rests; usually masonry, concrete, or stone, and
generally partially underground.
Function:
The action for which an item, component or system
is specially fitted or used or for which an item,
component or system exists; to be in action or
perform a task.
Functional:
Performing, or able to perform, a function.
Functional
drainage: A drain is functional when it
empties in a reasonable amount of time and is not
subject to overflow when one of its supply
faucets is left on.
Functional
Flow: Sufficient water flow to provide
uninterrupted supply to the highest, unrestricted
tap (faucet furthest from the source) when a
single intermediate, unrestricted tap is operated
simultaneously with uninterrupted flow.
Habitable:
In a condition suitable for human habitation.
Habitable
Spaces: Rooms or spaces used for sitting,
sleeping, bathing, toilets, eating or cooking.
Not considered habitable spaces by these
Standards are closets, halls, storage spaces and
utility areas.
Heat
Source: A heat source may be a radiator,
convector unit, radiant panel, heat pipe,
ductwork, grille, register, or other device(s)
from which heat is intended to be emitted.
Inspected
Property: The readily accessible areas of the
buildings, site, items, components, and systems
included in the inspection.
Intended
Function: Performing or able to perform the
usual function for which an item is designed, or
fitted; and be in a condition (state of repair)
appropriate to this function, its age and
location. [See Function]
Observe:
To see through visual directed attention.
Operate:
To cause equipment or systems that have been
activated to perform their intended function(s),
such as turning on a water faucet or turning up
the thermostat on an activated heating system.
Readily
Accessible: An item or component is readily
accessible if, in the judgement of the inspector,
it is capable of being safely observed without
movement of obstacles, detachment or
disengagement of connecting or securing devices,
or other unsafe or difficult procedures to gain
access.
Representative
Number: A sufficient number to serve as a
typical or characteristic example of the item(s)
inspected.
Shut-down:
A system or equipment is considered to be
shut-down when its normal control device(s) will
not cause it to become activated or operational.
The Inspector is not required to activate or
operate safety devices (fuses, breakers, etc.) in
the "off" position. It is not the
responsibility of the Inspector to put these
controls in the "on" mode, nor to
ensure that the equipment or systems to be tested
are operable at the time of the inspection.
Slab on
Grade: Structures that have no crawl space
and are in direct contact with the soil. Slabs
may or may not have supporting piers or pads.
Technically
exhaustive: An inspection is technically
exhaustive when it involves the use of
measurements, instruments, testing calculations
and other means to develop scientific or
engineering findings, conclusions, and
recommendations.
Verify:
To confirm or substantiate.
CODE OF ETHICS
To maintain
the integrity and high standards of skill and
practice in the home inspection profession, the
following rules of conduct and ethics shall be
binding upon the use of the Standards of Practice
(Standards) of the National Association of Home
Inspectors, Inc. (NAHI):
1. The
Inspector will act as a disinterested third party
and will discharge his duties with integrity and
fidelity to the public, with fairness and
impartiality to all parties.
2. The
Inspector shall uphold the honor and dignity of
this profession and avoid association with any
enterprise of questionable character or apparent
conflict of interest.
3. The
Inspector will express an opinion only when it is
based on practical experience and honest
conviction.
4. The
Inspector will always act in good faith toward
the client.
5. The
Inspector will not disclose any information
concerning the results of the inspection without
the approval of the client for whom the
inspection was performed.
6. The
Inspector will not accept compensation, financial
or otherwise, from more than one interested party
for the same service on the same property without
the consent of all interested parties.
7. The
Inspector will not accept nor offer commissions
or allowances, directly or indirectly, from other
parties dealing with the client in connection
with work for which the Inspector is responsible.
8. The
Inspector may provide "additional inspection
services" only after proper disclosure to
the client that the "additional inspection
services" are not part of the home
inspection, as defined by the NAHI Standards of
Practice. In addition, the sale of products or
correction of deficiencies are not permitted
under this Code of Ethics. The Inspector will
promptly disclose to the client any interest in
any business which may affect the client, the
quality or the result of the inspection.
9. The
Inspector shall make every effort to uphold,
maintain and improve the professional practice,
integrity and reputation of NAHI. He will report
all violations of this Code by other members, and
any other relevant information, to NAHI for
possible remedial action.
10. An
appraisal or opinion of the market value of the
inspected property will not be expressed by the
Inspector within the context of the inspection.